{"id":1146,"date":"2024-04-16T10:25:22","date_gmt":"2024-04-16T10:25:22","guid":{"rendered":"https:\/\/www.biotecitalia.com\/aesthetics\/?page_id=1146"},"modified":"2024-04-16T10:27:46","modified_gmt":"2024-04-16T10:27:46","slug":"cpl-applicator-calibrated-pulsed-light","status":"publish","type":"page","link":"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/","title":{"rendered":"CPL Applicator (Calibrated Pulsed Light)"},"content":{"rendered":"\t<section class=\"section dark\" id=\"section_1215524802\">\n\t\t<div class=\"bg section-bg fill bg-fill  \" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\t<div class=\"ux-shape-divider ux-shape-divider--bottom ux-shape-divider--style-waves-opacity\">\n\t\t<svg viewBox=\"0 0 1000 300\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" preserveAspectRatio=\"none\">\n    <path class=\"ux-shape-fill\" d=\"M0 300L-1 69.71C216 57 299.47 198.86 403 226C506 253 577 196 660 197C740 198 790.09 234.07 874 267C935.23 291 982 282.61 1000 277.61V300H0Z\"\/>\n    <path class=\"ux-shape-fill\" opacity=\"0.5\" d=\"M1 265.094L0 50.5C217 37.79 300.47 186.36 404 213.5C507 240.5 578 196.5 661 197.5C741 198.5 787.59 239.57 871.5 272.5C932.73 296.5 980.5 284.5 998.5 279.5V298.5L1 265.094Z\"\/>\n    <path class=\"ux-shape-fill\" opacity=\"0.15\" d=\"M0.999878 244.094L-0.00012207 27C217 14.29 300.47 173.86 404 201C507 228 578 196 661 197C741 198 787.59 243.07 871.5 276C932.73 300 980.5 284.5 998.5 279.5V299L0.999878 244.094Z\"\/>\n<\/svg>\n\n\t<\/div>\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1932524916\">\n\n\t<div id=\"col-687483208\" class=\"col medium-6 small-12 large-6\"  >\n\t\t\t\t<div class=\"col-inner text-left\"  >\n\t\t\t\n\t\t\t\n<h2>CPL Applicator (Calibrated Pulsed Light)<\/h2>\n<h1>\u00a0<\/h1>\n<h1><strong>SUPREME<br \/><\/strong><\/h1>\n<h6>TECHNICAL SPECIFICATIONS AND FOCUS ON THE TECHNOLOGY<\/h6>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1215524802 {\n  padding-top: 150px;\n  padding-bottom: 150px;\n}\n#section_1215524802 .section-bg.bg-loaded {\n  background-image: url(https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-hero-bkg2@2x-scaled-1.jpg);\n}\n#section_1215524802 .section-bg {\n  background-position: 22% 32%;\n}\n#section_1215524802 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_1215524802 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>\n\t\n\t<section class=\"section\" id=\"section_1912683217\">\n\t\t<div class=\"bg section-bg fill bg-fill  bg-loaded\" >\n\n\t\t\t\n\t\t\t\n\t\t\t\n\n\t\t<\/div>\n\n\t\t\n\n\t\t<div class=\"section-content relative\">\n\t\t\t\n<div class=\"row\"  id=\"row-1398110675\">\n\n\t<div id=\"col-1413143413\" class=\"col small-12 large-12\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<h3>Focus on the technology<\/h3>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1058744142\">\n\n\t<div id=\"col-1201173238\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover bord-a x md-x lg-x y md-y lg-y\" id=\"image_1649306422\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1100\" height=\"720\" src=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-09@2x.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-09@2x.jpg 1100w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-09@2x-611x400.jpg 611w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-09@2x-768x503.jpg 768w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-09@2x-600x393.jpg 600w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1649306422 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t<div class=\"img has-hover bord-a x md-x lg-x y md-y lg-y\" id=\"image_1795334656\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1100\" height=\"720\" src=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-10@2x.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-10@2x.jpg 1100w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-10@2x-611x400.jpg 611w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-10@2x-768x503.jpg 768w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-10@2x-600x393.jpg 600w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1795334656 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1375847366\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div id=\"text-2416129742\" class=\"text\">\n\t\t\n<h5>BIOSTIMULATION<\/h5>\n\t\t\n<style>\n#text-2416129742 {\n  color: #b99700;\n}\n#text-2416129742 > * {\n  color: #b99700;\n}\n<\/style>\n\t<\/div>\n\t\n<p>The most effective solution to treat facial blemishes, thanks to the selectivity of the photo-thermolysis effect<\/p>\n<ul>\n<li>The special reflective cavity, coated in platinum, generates high energy density in the CPL module. The user-friendly system is simple to use and allows the operator to easily set all the treatment parameters.<\/li>\n<li>The energy impacts on the nature of the light-fabric interaction and the operator can increase the value up to 26J \/ cm2.<\/li>\n<li>The pulse duration can be adjusted by the operator by selecting the duration from 10 to 50 ms.<\/li>\n<li>The time interval between one micro pulse and the next, makes it possible to modulate the release of energy in relation to the skin\u2019s cooling time.<\/li>\n<li>The Cut-off filters of the CPL handpiece emit in a range between 600 and 1100 nm and offer the possibility to use up to 5 wavelengths to adapt the treatment to the phototype and to the target\/skin problem to be treated.<\/li>\n<\/ul>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1100789524\">\n\n\t<div id=\"col-964095965\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover bord-a x md-x lg-x y md-y lg-y\" id=\"image_1748393957\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1100\" height=\"720\" src=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-11@2x.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-11@2x.jpg 1100w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-11@2x-611x400.jpg 611w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-11@2x-768x503.jpg 768w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-11@2x-600x393.jpg 600w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1748393957 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-411472204\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p>Aluminium reflector cavity. Optimises lamp irradiance and generates an intense light beam that increases energy efficiency.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-339286677\">\n\n\t<div id=\"col-293122781\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover bord-a x md-x lg-x y md-y lg-y\" id=\"image_173305799\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1100\" height=\"720\" src=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-12@2x.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-12@2x.jpg 1100w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-12@2x-611x400.jpg 611w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-12@2x-768x503.jpg 768w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-12@2x-600x393.jpg 600w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_173305799 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1588167634\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p>The glass prism that guides the light and remains in direct contact with the skin. It cools down to protect the skin before, during and after the light transmission.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-1806738997\">\n\n\t<div id=\"col-1268452449\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover bord-a x md-x lg-x y md-y lg-y\" id=\"image_1651976133\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1100\" height=\"720\" src=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-13@2x.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-13@2x.jpg 1100w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-13@2x-611x400.jpg 611w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-13@2x-768x503.jpg 768w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-13@2x-600x393.jpg 600w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_1651976133 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-2081611149\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p>The Xenon lamp, it allows a rapid coverage of the treatment area, permitting one to operate with a maximum frequency of 3 pulses a second.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n<div class=\"row\"  id=\"row-846336956\">\n\n\t<div id=\"col-1654608522\" class=\"col medium-4 small-12 large-4\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n\t<div class=\"img has-hover bord-a x md-x lg-x y md-y lg-y\" id=\"image_97662806\">\n\t\t\t\t\t\t\t\t<div class=\"img-inner dark\" >\n\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1100\" height=\"720\" src=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-14@2x-1.jpg\" class=\"attachment-original size-original\" alt=\"\" srcset=\"https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-14@2x-1.jpg 1100w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-14@2x-1-611x400.jpg 611w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-14@2x-1-768x503.jpg 768w, https:\/\/www.biotecitalia.com\/aesthetics\/wp-content\/uploads\/2024\/01\/supreme-tech-14@2x-1-600x393.jpg 600w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n<style>\n#image_97662806 {\n  width: 100%;\n}\n<\/style>\n\t<\/div>\n\t\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n\n\t<div id=\"col-1647640309\" class=\"col medium-8 small-12 large-8\"  >\n\t\t\t\t<div class=\"col-inner\"  >\n\t\t\t\n\t\t\t\n<p>A lateral slot allows the operator to modify the filtering of the lamp wavelength, thus adapting the light emission to the treatment.<\/p>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\n\t\n<\/div>\n\t\t<\/div>\n\n\t\t\n<style>\n#section_1912683217 {\n  padding-top: 30px;\n  padding-bottom: 30px;\n}\n#section_1912683217 .ux-shape-divider--top svg {\n  height: 150px;\n  --divider-top-width: 100%;\n}\n#section_1912683217 .ux-shape-divider--bottom svg {\n  height: 150px;\n  --divider-width: 100%;\n}\n<\/style>\n\t<\/section>\n\t\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":1134,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"_joinchat":[],"footnotes":""},"class_list":["post-1146","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>CPL Applicator (Calibrated Pulsed Light) - Biotec Italia<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"CPL Applicator (Calibrated Pulsed Light) - Biotec Italia\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/\" \/>\n<meta property=\"og:site_name\" content=\"Biotec Italia\" \/>\n<meta property=\"article:modified_time\" content=\"2024-04-16T10:27:46+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/\",\"url\":\"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/\",\"name\":\"CPL Applicator (Calibrated Pulsed Light) - Biotec Italia\",\"isPartOf\":{\"@id\":\"https:\/\/www.biotecitalia.com\/aesthetics\/#website\"},\"datePublished\":\"2024-04-16T10:25:22+00:00\",\"dateModified\":\"2024-04-16T10:27:46+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.biotecitalia.com\/aesthetics\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Technologies\",\"item\":\"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Supreme\",\"item\":\"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"CPL Applicator (Calibrated Pulsed Light)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.biotecitalia.com\/aesthetics\/#website\",\"url\":\"https:\/\/www.biotecitalia.com\/aesthetics\/\",\"name\":\"Biotec Italia\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.biotecitalia.com\/aesthetics\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"CPL Applicator (Calibrated Pulsed Light) - Biotec Italia","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/","og_locale":"it_IT","og_type":"article","og_title":"CPL Applicator (Calibrated Pulsed Light) - Biotec Italia","og_url":"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/","og_site_name":"Biotec Italia","article_modified_time":"2024-04-16T10:27:46+00:00","twitter_card":"summary_large_image","twitter_misc":{"Tempo di lettura stimato":"2 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/","url":"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/","name":"CPL Applicator (Calibrated Pulsed Light) - Biotec Italia","isPartOf":{"@id":"https:\/\/www.biotecitalia.com\/aesthetics\/#website"},"datePublished":"2024-04-16T10:25:22+00:00","dateModified":"2024-04-16T10:27:46+00:00","breadcrumb":{"@id":"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/cpl-applicator-calibrated-pulsed-light\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.biotecitalia.com\/aesthetics\/"},{"@type":"ListItem","position":2,"name":"Technologies","item":"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/"},{"@type":"ListItem","position":3,"name":"Supreme","item":"https:\/\/www.biotecitalia.com\/aesthetics\/en\/technologies\/supreme\/"},{"@type":"ListItem","position":4,"name":"CPL Applicator (Calibrated Pulsed Light)"}]},{"@type":"WebSite","@id":"https:\/\/www.biotecitalia.com\/aesthetics\/#website","url":"https:\/\/www.biotecitalia.com\/aesthetics\/","name":"Biotec Italia","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.biotecitalia.com\/aesthetics\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"}]}},"lang":"en","translations":{"en":1146,"it":642,"es":1538,"de":1548,"fr":1883,"pl":2539},"pll_sync_post":[],"_links":{"self":[{"href":"https:\/\/www.biotecitalia.com\/aesthetics\/wp-json\/wp\/v2\/pages\/1146","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.biotecitalia.com\/aesthetics\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.biotecitalia.com\/aesthetics\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.biotecitalia.com\/aesthetics\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.biotecitalia.com\/aesthetics\/wp-json\/wp\/v2\/comments?post=1146"}],"version-history":[{"count":2,"href":"https:\/\/www.biotecitalia.com\/aesthetics\/wp-json\/wp\/v2\/pages\/1146\/revisions"}],"predecessor-version":[{"id":1149,"href":"https:\/\/www.biotecitalia.com\/aesthetics\/wp-json\/wp\/v2\/pages\/1146\/revisions\/1149"}],"up":[{"embeddable":true,"href":"https:\/\/www.biotecitalia.com\/aesthetics\/wp-json\/wp\/v2\/pages\/1134"}],"wp:attachment":[{"href":"https:\/\/www.biotecitalia.com\/aesthetics\/wp-json\/wp\/v2\/media?parent=1146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}