COAXMED ONE

Multiple Body technologies

TECHNICAL SPECIFICATIONS AND FOCUS ON THE TECHNOLOGY

COAXMED ONE

Multiple Body technologies

TECHNICAL SPECIFICATIONS AND FOCUS ON THE TECHNOLOGY
SUPPLY VOLTAGE 240 Vac 50/60 Hz
MAXIMUM POWER 450 VA
FUSES 2 x F4A 250 V
MAXIMUM VACUUM 66.6 kPa
MINIMUM CRYO TEMPERATURE -10°C
SAFETY CLASS AND TYPE OF PART APPLIED I BF
RISK CLASSIFICATION ON THE BASIS OF 93/42/CEE Class IIb
DIMENSIONS (W x D x H) 450 x 500 x 420 mm
MAXIMUM WEIGHT (WITH HANDPIECES) 42 kg
 
FREQUENCY 28 kHz
MAXIMUM POWER 35 W
OPERATING MODES Continuous and pulsed
ACTIVATION Pedal
 
NUMBER OF LASER DIODES 4
WAVELENGTH 808nm ± 5nm
OUTPUT POWER CW PER DIODE 3m W (single)
 
MINIMUM TEMPERATURE -10°C
MAXIMUM SUCTION 66.6 kPa
OPERATIVE MODE Continuous
ACTIVATION Touchscreen button
 
FUNCTION Bipolar/Monopolar
FREQUENCY 300 kHz to 1000 kHz
WAVE SHAPE Amplitude modulated signal
MAXIMUM POWER 130 W
OPERATING MODES Continuous and pulsed
ACTIVATION Pedal

DUOSHAPE

In ABS material, the handpiece is electrically and thermally insulated, protecting patient and operator.

The ergonomics, the manageability and the low weight of the handpiece make the treatment simple and fast, facilitating the fluidity of the movements.

Designed to manage monopolar radiofrequency and cavitational ultrasound simultaneously or individually.

Ultrasound frequency stable at 28KHz, guarantees safety and selectivity of action.

3Density mode that automatically modulates the frequency of the radio frequency flow for a three-dimensional and homogeneous penetration of thermal energy.

PerfectTune mode with water cooling of the ultrasonic transducer that guarantees efficacy, safety and comfort.

VACULASE

In ABS material, the handpiece is electrically and thermally insulated, protecting patient and operator.

With low weight, it facilitates the movements of the specialist.

The ergonomics of the handpiece makes it easy to handle, for comfortable use.

It combines biostimulating laser, cryo and vacuum.

Designed for two functions: in treatments for oxygenation and detachment of tissues and in lymphatic drainage.

Easy connection with automatic recognition that allows the swapping from the vaculase handpiece to the cryoliposculpt handpiece quickly and in total safety.

CRYOLIPOSCULPT

In ABS material, the handpiece is electrically and thermally insulated, protecting patient and operator.

With a low weight, the suction of the handpiece anchors it firmly to the area to be treated.

The ergonomics of the handpiece makes it easy to handle, and fits perfectly on the profile of the areas to be treated.

The metal plates, in medical grade AISI 316 LVM stainless steel, have excellent corrosion resistance and exceptional thermal conduction characteristics, making the treatment safer and more effective.

The medium handpiece with double applicator allows you to treat two different adiposity areas in the same session.

Mini combo kit, consisting of three small handpieces for defining facial contouring or for small adiposity of the body.

Focus on the technology

DuoShape

The low frequency 28 KHz ultrasound transforms electricity into cavitational waves. Inside the tissues, they cause the breakdown of the cell membrane of the adipocytes, inducing the release of lipids which will then be reabsorbed (lymphatic circulation) or eliminated (lymph nodes and digestive system).

Vaculase

The synergistic and combined action of laser, cryo and rhythmic vacuum, stimulates the elimination of excess liquids and the toxic substances contained in them, making it particularly effective for combating panniculopathy in the early stages of evolution, when edema and water retention are present.

Focus on Cryoliposculpt® technology

TissueActive®

Preserves the vascularization of the tissue thanks to the synergy of the Coolfrequency® and Vacupulse® technologies.

Vacupulse®

Active suction that causes the detachment of the tissues and modifies the resistance and elasticity of the connective tissue by keeping the tissues in motion and stimulating the microcirculation.

Uniform cooling

The rapid absorption of cold with high heat exchange capacity – due to the ergonomics of the applicator – ensures a stable and uniform temperature down to -10°C.

Coolfrequency®

It stimulates intra and extracellular ion exchange, allowing correct cell functionality and contributes to the elimination of the “ice block” effect in the portion of treated tissue.

Thermal monitoring

It constantly monitors the temperature reached on the skin, reporting the data on the display, ensuring safe and reproducible protocols.

Double applicator

Possibility to treat two different adiposity areas in the same session.